Operating manual
EN
for the user
"HOME" display
16:20
Manual mode
Fig. 3.14
MANUAL operating mode
08:16
Fig. 3.15
AUTOMATIC operating mode
Operating keys in the "HOME" display
ON
The pellet fireplace is ready for operation after pressing
the button (min. 2 seconds).
On = red (shown as deep black in this manual)
OFF
The pellet fireplace is ready for operation after pressing
the button (min. 2 seconds).
Off = black (shown as dark grey in this manual)
PLUS
Increase the output stage (manual) or the target tempera-
ture (automatic)
Minus
Decrease the output stage (manual) or the target temper-
ature (automatic)
MENU
Selection options for submenus (see above)
We reserve the right to make technical changes
17
Actual °C
4
Ready
Party
17
Ist in °C
AUTO mode
25
Desired °C
Ready
Party
PARTY FUNCTION ON
The party function is switched on by a long press of the
"Party button", i.e. the preset switching times (see "Timer
program") are ignored and the pellet fireplace heats at the
output stage which is set.
If switched on in the "Heating operation" operating state,
the next "switch-off time" is ignored, the pellet fireplace
continues heating. The party function automatically
switches off at the next switch-on time and the pellet fire-
place resumes working as programmed.
If switched on in the "Ready" operating state, the "switch-
off time" which has already occurred is ignored and the
pellet fireplace ignites in order to start heating operation.
The party function automatically switches off at the next
switch-on time and the pellet fireplace resumes working
as programmed.
PARTY FUNCTION OFF
The party function can be manually switched off by press-
ing the "Party button" again.
"Operating state" display
SWITCHED OFF
The pellet fireplace is switched off by pressing the "ON/
OFF button". Automatic start (heating operation) cannot
occur in this operating state. Exception: frost protection
(see "Frost protection" chapter)
READY
Heating is enabled by pressing the "ON/OFF button". Since
all of the conditions for starting the combustion process
are not met, the ignition process is not started. Instead, the
pellet fireplace is put into the "Ready" operating state. The
following conditions must be met to directly start the igni-
tion process:
- No outstanding error message
- Combustion chamber door closed
- Pellet reservoir cover closed
- No relay test is currently being performed (service)
- Flame temperature has cooled to below 100 °C
- The connected external room temperature sensor
contact is closed.
- The room temperature has dropped to the set value.
- The current time is within the switching time
(with switching time active).
IGNITION
The pellets are automatically deposited in the burner
trough and ignited. Ignition takes longer during initial
commissioning because the screw conveyor is filled with
pellets first. An extended special ignition program is
started after an error message.
START
The pellet volume is steadily increased until the maximum
output stage is reached.
HEATING OPERATION
The pellet fireplace heats to the output stage which is set.
VESTA 6 kW
55