Installation instructions
EN
for the specialist company
2 Installation instructions (for the specialist company)
2.1 Delivery
The heater is delivered pre-assembled.
● Remove the packaging and check the scope of delivery!
● Report visible damage to Olsberg!
1
Fig. 2.1
Scope of delivery
1
Pre-assembled pellet fireplace
2
Manual
3
Bridge plug
4
Gloves
5
Energy label
2.2 Necessary tools
The tools and materials required on site are determined by the
specialist company and by the conditions in the place of installation.
The following tools are required for installation of the pellet fire-
place:
ū Clean protective gloves
ū Cutter knife
ū Spirit level
Fig. 2.2
Necessary tools
40
2
3
4
5
VESTA
43-316
A
+++
A
A
++
+
A
++
A
+
A
A
+
A
+
B
C
D
E
F
G
6,3
kW
ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI
2015/1186
2.3 Type plate
Raumheizer zur Verfeuerung von Holzpellets
Room heater for burning wood pellets
Gerätetyp
Device typ
Leistungserklärung Nr.
Declaration of performance
Prüfstellen Nr.
Test center no.
Fabrikations- Nr.
Serial no.
Bauaufsichliche
Building authority no
Zulassung Nr.
Nominal heat output
Nennwärmeleistung
(NWL)
(NWL)
Teilwärmeleistung
Partial heat output
(TWL)
(TWL)
Raumwärmeleistung
Room heating output
(NWL / TWL)
(NWL/TWL)
Wasserwärmeleistung
Water heat output
(NWL / TWL)
max. Betriebsdruck
max. operating pressure
Fuel: wood pellets
Abgastemperatur am
Flue gas temperature
Stutzen (NWL / TWL)
exhaust socket NWL
Wirkungsgrad
(NWL / TWL)
CO-Emission
CO-emissions
(NWL / TWL)
(NWL/TWL)
Staub
Dust quantity
(NWL / TWL)
(NWL/TWL)
Stromversorgung
Power supply
operation
max. Leistung Betrieb /
max. Power
Zündung
/ ignition
Mindestabstand zu
Minimum distance to
combustible components:
brennbaren Bauteilen:
back / side/ front /
hinten, seite, vorn,
back side
unten
Nur empfohlene Brenn-
Use only recommended
fuels!
Bedienungsanleitung
Read and follow the
operating instructions!
lesen und befolgen!
Olsberg Gmbh
EN 14875:2006 / EN 16510-1:2018
Hüttenstraße 38
22
59939 Olsberg
Fig. 2.3
Type plate
VESTA 6 kW
Type d´appareil
VESTA
43/3161
43316-CPR-
No. de déclaration de performance
2022/01/18
1476
No. laboratoire d´essaie
No. de fabrication
No. approbation de l'in
Z-43.12-352
spection des bâtiments
Puissance nominale (PW)
6,0 kW
Puissance partielle (PP)
Puissance nominale à l´air
6,0 kW
(PW)
Puissance calorifique de l´eau
Pression de service max. de l´eaue
Carburants : granulés á bois
Température des fumés
165 °C
au manchon de raccord
Rendement (PW)
> 85 %
Emission CO (PW/PP)
< 250 mg/m³
Teneur en poussière (PW/PP)
< 20 mg/m³
1/N/PE ~ 230 V
Alimentation électrique
Fonctionnement à puissance
42 / 298 W
max. / allumage
Distance minimale aux matières
10 cm /10 cm
combustibles: harrière / côté devant
/ bas
/ 80 cm / 0 cm
N'utilisez que les car burants
recommandés!
Olsberg
Werk 87
Lisez et suivez l´instruction
d'utilisation!
Z-43.12-352
RRF
15a B-VG
We reserve the right to make technical changes
XXX
npd
npd
npd