Installation instructions
EN
for the specialist company
Fig. 2.12
Install the lower back wall
Installation of a combustion air damper for automatic opening
and closing of the combustion air line (optional)
A closed combustion air line prevents warm air from escaping from
the installation room unnecessarily with the stove turned off.
Note! The combustion air damper is closed in the "Off" operat-
ing state. It is open in all other operating states ("Ready", "Ignition",
"Start", etc.).
The actuator takes approx. 2 minutes to reach the "closed" posi-
tion, i.e. the pellet fireplace may be switched off at the master
switch 2 minutes after "Off" appears on the display at the earliest.
The user of the pellet fireplace should also be informed of this.
We reserve the right to make technical changes
9x
3
Fig. 2.13
Connection of a motor-driven combustion air damper
1
Motor slewing ring
2
Stops for the combustion air damper (open/closed)
3
"S19" connector
4
"L continuous" connector (must be connected to the
"L continuous" mating connector in the wiring harness)
5
"S5" connector
6
Combustion air damper screwed onto the rear
7
Combustion air damper screwed onto the bottom
5
4
3
2
VESTA 6 kW
1
2
6
7
45