The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396. The
installation must be done observing the norms in force particularly concerning room ventilation and discharging gas
emissions.
N.B. The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, maintenance or use of the appliance, as in all the other cases considered in the items of our sales conditions.
DIMENSIONS
MODEL
cm
FTL-94G
40x90x90h
FTR-94G
40x90x90h
FTL-94GS
40x90x90h
FTR-94GS
40x90x90h
FTL-98G
80x90x90h
FTLR-98G
80x90x90h
FTL-98GS
80x90x90h
FTLR-98GS
80x90x90h
FTR-98G
80x90x90h
FTR-98GS
80x90x90h
L= Smooth hotplate R= Corrugated hotplate
L/R= ½ Smooth +1/2 Corrugated
S= Chromium-plated hotplate
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
The gas installation, the electrical connections and the rooms in which the appliances are installed must comply
with the norms in force in the Country in which the installation is effecte; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2
installed.
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
• safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer's instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
a) General indications (Rules valid for GB only)
- For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water
Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British Standards
(latest editions) concerned.
The installation, transformation and repair of appliances for professional kitchens as well as removal due to
malfunction,
and the supply of gas, may be made only by means of a maintenance contract stipulated with an authorised sales office
and in observance of technical regulations.
GB
DECLARATION OF COMPLIANCE
INSTALLATION
DIMENSIONS
MODEL
FTLT-94G
40x90x29h
FTRT-94G
40x90x29h
FTLT-94GS
FTRT-94GS
40x90x29h
FTLT-98G
80x90x29h
FTLRT-98G
80x90x29h
FTLT-98GS
FTLRT-98GS
80x90x29h
FTRT-98G
80x90x29h
FTRT-98GS
80x90x29h
INSTALLING THE APPLIANCE
CHECKING FOR ADEQUATE VENTILATION
Installation rules
IE
NOMINAL HEAT
OUTPUT
cm
TOTAL KW
40x90x29h
18
18
80x90x29h
18
18
18
18
24
GAS CONNECTION
ISO 7-1
9
R 1/2"
9
R 1/2"
9
R 1/2"
9
R 1/2"
R 1/2"
R 1/2"
R 1/2"
R 1/2"
R 1/2"
R 1/2"
3
/h per kW of power
m