through the stove the installer will have provided alternative means, such as a soot door. After sweeping the chimney the stove
flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush.
Periods of Prolonged Non-Use
If the stove is to be left unused for a prolonged period of time then it should be given a thorough
clean to remove ash and unburned fuel residues. To enable a good flow of air through the appliance
to reduce condensation and subsequent damage, leave the air controls fully open.
Extractor fan
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes
into the room.
Aerosol sprays
Do not use an aerosol spray on or near the stove when it is alight.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite. If the fire bed is too
low or cool, suitable kindling must be used to re-light fires
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
Use with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open
except as directed in the instructions.
Dampers left open
Operation with the air controls or dampers open can cause excess smoke. The appliance must not be operated with air controls or
dampers left open except as directed in the instructions.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn off
the stove immediately and isolate the mains electricity supply (if applicable), and tightly close the doors of the stove. This should
cause the chimney fire to go out. If the chimney fire does not go out when the above action is taken then the fire brigade should
be called immediately. Do not relight the stove until the chimney and flueways have been cleaned and examined by a
professional.
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. In accordance with
current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed
to provide combustion air. This air vent should not under any circumstances be shut off or sealed.
USER OPERATING INSTRUCTIONS
Please read the important notices given above before referring to the main instruction book for detailed operating instructions.
Recommended fuels
Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the main stove manuals.
HETAS Ltd Approval
HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Approval does not cover the use
of other fuels either alone or mixed with the recommended fuel, nor does it cover instructions for the use of other fuels.
50