Télécharger Imprimer la page

TermaTech TT44 Serie Notice De Montage Et D'utilisation page 36

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
3.
Ignite the two firelighters (See Figure 3.1) and leave the door slightly ajar using the small bracket in the upper right
corner of the door (See Figure 3.2). Keep the door ajar for approximately 3 minutes before closing it completely. Once
the door is closed, set the air control handle to 100% combustion air (full secondary air) (See Figure 3.3).
Figure.3.1.
4.
When the kindling fire has burned down and only embers remain, open the door gently to prevent ash from swirling out.
Then, carefully spread the embers using a fire rake, so they are evenly distributed across the bottom of the stove (See
Figure 4.1). Use a glove to protect against burns.
Figure.4.1.
5.
Next, place 2 logs weighing approximately 590 grams each and measuring 22 cm in length inside the stove. Lay the logs
parallel to the back of the stove, with one log positioned about 2 cm away from the back. Ensure that the logs are evenly
spaced from the sides of the stove. The gap between the two logs should be approximately 1 cm (See Figure 5.1). Close
the door completely. For the next 1 minute and 30 seconds, set the air control handle to 100% startup air (full primary +
secondary air) (See Figure 5.2). After 1 minute and 30 seconds, adjust the air control handle to full combustion air (See
Figure 5.3). Keep the air control handle in this position in 30 seconds. After 30 seconds, set the handle to 50%
combustion air (secondary air) (See Figure 5.4).
6.
Figure.5.1.
7.
When the fire has burned down to embers, approximately after 47 minutes (See Figure 6.1), you can reload and start a new
TermaTech A/S, Gunnar Clausens Vej 36, DK-8260 Viby J
Figure.3.2
Figure.3.3.
Figure.5.2.
Figure.5.3.
www.termatech.com
Figure.5.4.
03-07-2024 LP
Item no. 99-291 / 101-212
36

Publicité

loading

Ce manuel est également adapté pour:

Tt44s