8.4
Adjustment of Levelling Feet
There are installed levelling feet under the stove. Levelling feet are used if the floor is uneven or if you want an optical "floating"
stove, or if you want to use a custom-cut floor plate. Alternatively, you can let the stove stand on the base plate. If a custom-cut
floor plate is used, the levelling feet should be installed/used/adjusted for this purpose. Otherwise, the custom-cut floor plate
cannot be installed. Note that all specified measurements (on the stove) are without levelling feet. If you use levelling feet, the
stove will be correspondingly higher.
Note: All dimension on the stove is without the adjustable feet's. If there is used adjust able feet's is the stove similarly higher.
8.5
Adjustment of the draft in the door
TermaTech A/S, Gunnar Clausens Vej 36, DK-8260 Viby J
The four feet is easy to adjust from the
compartment room with and unbrako key.
Se the four white arrow.
The adjustable feet's have to be adjusted
with a distance between the bottom plate
and the floor at approx. 8mm depending of
the floorplate.
Weaker / less draft in the door:
Loosen the two screws the two screws No. 1 and No. 2. Push the
bracket with the magnet backward and tighten screws again.
Stronger / more draft in the door:
Loosen the two screws No. 1 and No. 2. Pull the bracket against
the door and tighten the screws again.
Note: We recommend a draft of 4 to 6 kg. The door may not hit
the magnet. Distance between door and magnet should be a
minimum of 1mm.
www.termatech.com
03-07-2024 LP
Item no. 99-291 / 101-212
45