8.2
TT44, TT44S: Replacement of insulation panels
8.3
Adjusting the self-closing door mechanism (Bauart 1)
In the compartment room is a bracket and a spring. They are a part of the bau- art function They will close the door when you
release the handle on the door.
De activate the Bauart /Auto closing function: Demount the spring No.1 from bracket No. 2. After that demount the pass-
screw No. 3
The Bauart /Auto closing function is not and requirements in Denmark, Sweden and Norway.
TermaTech A/S, Gunnar Clausens Vej 36, DK-8260 Viby J
1.
First, lift smoke plate No. 2 a little. After that
remove the backplate No. 1.
2.
After that remove the smoke plate No. 2.
3.
Then remove the two plate in left and right side
No. 3 and No.4
4.
After that remove the two plates in the corner
plate No. 5 and No.6.
Installation of Vermiculite: This is done in the reverse
order. Start with Nr.6, then Nr.5, and etc...