TCD 2044
2.0 - INSTALLATION
2.3 - Electric connections
The control complies with EMC standards (electromagnetic compatibility) but requires correct installation to avoid com-
promising its performance and that of the surronding instruments.
For this reason the interface wires must be positioned at a distance of at least:
• 1 m from cables that transmit radio signals (except for SSB radio transmitters).
• 2 m from cables for SSB radio transmitter signals.
Follow the rules below to construct the electrical installation relative to the control:
• Connect the control connector to the connector coming from the thruster.
• Fit a switch to turn the control on and off (not supplied).
• Position the switch so that it can be easily reached when the device must be turned off to prevent dangerous situations.
• Insert a 8A fast-blow fuse on the control power supply line (not supplied).
• Use cables with a cross-section appropriate for their lenght to supply the control.
• Do not use voltage from the motor or thruster battery groups to power the control.
• Check that all electrical connections are correct before powering the control.
Thruster basic system
RED
RED
(1)
SERVCE
BATTERY
BLACK
(2)
(2)
BLACK
(2)
(2)
INSTALLATION AND USE MANUAL - REV 002A
(1) WARNING: COMMON NEGATIVE FOR THE BATTERY GROUPS
(2) EXTENSION CORD (OPTIONAL)
(3) SPLITTER (OPTIONAL)
MOTOR
(3)
BOW THRUSTER
MOTOR
(3)
STERN THRUSTER
EN
(1)
BOW
THRUSTER
(1)
STERN
BATTERY
19