12.

MalfuncTiOns

Malfunctions
Actuator does not switch
Valve is not sealed
Flow rate reduced
32
Control connection interchanged*
CFA:
CFB:
CFI
* see Figure 16: Pneumatic connection
Control pressure too low
See pressure specifications on the rating plate.
Medium pressure too high
See pressure specifications on the rating plate.
Medium pressure too high
See pressure specifications on the rating plate.
Control pressure too low
See pressure specifications on the rating plate.
PTFE diaphragm bulging
Replace diaphragm.
english
cause / remedial action
Connect lower control connection
Connect upper control connection
Upper control connection: Close
Lower control connection: Open
Type 2 030, 2031, 2031 K, 2032,
2033, 2037