procedure for control function a
→
Pressurize lower control air connection with compressed air (value as indicated on the rating plate) (see
Figure 15: Control air connection).
→
Place actuator on the housing.
→
Lightly cross-tighten the housing screws until the diaphragm is between the housing and actuator.
do not tighten the screws yet.
→
Actuate the diaphragm valve twice to position the diaphragm correctly.
→
Without applying pressure, tighten the housing screws to the permitted tightening torque
torques for diaphragms).
→
Pressurize lower control air connection with compressed air (value as indicated on the rating plate).
→
Check the tightening torque of the screws again.
procedure for actuator with control functions B and i:
→
Place actuator on the housing.
→
Lightly cross-tighten the housing screws without pressurization until the diaphragm is between the housing
and actuator.
do not tighten the screws yet.
→
Pressurize upper control air connection with compressed air (value as indicated on the rating plate) (see picture
below Figure 15: Control air connection).
→
Actuate the diaphragm valve twice.
→
Tighten the housing screws to the permitted tightening torque
diaphragms)
Figure 15:
Control air connection
tightening torques for plastic housing, Va tubular housing (Va) and forged housing
dn
65
80
100
Table 7:
Tightening torques for diaphragms
Installation
elastomer - diaphragm
(see Table 7: Tightening torques for
Upper control air connection
(for CFB and CFI)
Lower control air connection
(for SFA and SFI)
tightening torque [nm] (values for guidance)
20
30
40
(see Table 7: Tightening
ptfe - diaphragm
30
40
50