Vending machine can point out some possible bad operations.
Click on the
by selecting the
To check the status of the inputs, go to the Input status
parameters
E
N
G
NB: for all errors prior to no.100, refer to the Snack & Food manual.
L
I
S
H
ERROR MESSAGE
101 Coffee cake collector
full
102 Waste level
103 Water missing
104
Cup Holder Empty
105
Nozzles movement
error
FAS International S.r.l. - 60 Via Lago di Vico - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
This section is for qualified assistance staff only
Error log icon to see the list (if there is one). All the alarm conditions can then be eliminated
Reset error log icon.
-> Services
SUB
CAUSE OF THE ERROR
CODE
The maximum number of
coffee cakes entered in the
menu "Settings->Machine
parameters->Used coffee
cakes" has been reached
max. waste level reached
water supply missing
Cups are missing (still 3
deliveries are available
during turret change)
1
The nozzles are unable to
complete the reset cycle
when the machine is
restarted
2
Incorrect microswitch
movement when dispensing
position is reached
3
The nozzles are unable to
reach the dispensing
position
4
The nozzles are unable to
return to the home position
5
Incorrect microswitch
movement when returning
to the home position
13
ERRORS
menu underneath the menu Machine
FAS VICTORIA - ISSUE 00
SOLUTION
Empty the coffee cake collector and reset
the alarm or zero-set the number in the
"Used coffee cakes" menu
Enter 0 for the "Used coffee cakes alarm"
item if this alarm is not required
Empty the waste bin
Make sure the waste level microswitch is
working properly
check correct opening of outer tap
check that there is no contraction in the inlet
hose
check correct functioning of the inlet valve
load cups
Make sure the cup presence microswitch
(CPB) is working properly
Check the correct operation of the column
change gear motor (MC)
Remove any possible obstacles.
Remove any possible dirt from inside the
assembly.
Make sure the nozzle microswitch (CDB) is
working properly.
Make sure the nozzle movement gearmotor
(MTBC) is working properly.