FAS VICTORIA - ISSUE 00
COFFEE UNIT, COFFEE UNIT PRESENCE CONTROL
Infusion chamber is driven by a gear motor (MRGC) through a joint.
Microswitches MCRG - MCPG define the work positions of the unit during the coffee cycle, specifically:
• MCGR = OPEN UNIT POSITION
• MCPG = CLOSED UNIT POSITION (defines the motor stop in rest/dispensing position, infusion pump start,
opening of coffee solenoid valve.)
The coffee unit operation is managed by a microswitch (CPGC) which detects its presence in the support: if
the coffee unit is installed, it works properly otherwise the following functions are inhibited
•
Service function for the coffee unit feed
•
Service function for rinsing cycle for coffee unit
•
Service function for coffee grinding
•
Service function for ground coffee dosage
•
Inhibition of all the selections for espresso coffee + instant
FAS International S.r.l. - 60 Via Lago di Vico - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: