22
CONTROL CARD
The control card, located inside the vending machine, houses the central control unit, which oversees all
machine operations and control of the sensors.
ANDROID BOX CARD
It is inside the vending machine door. It is used to send and receive data to/from the control board and the
touch screen monitor.
WATER INLET SOLENOID VALVE
E
The water inlet solenoid valve, located on the back of the
N
vending machine, can be accessed from inside. It is fitted
G
with a mechanical device that automatically stops the water
L
from entering in the event of a problem with the solenoid
I
valve itself or the water circuit.
S
To reset normal operation, proceed as follows:
H
•
Switch off the machine by means of the main switch and
pull out the power plug;
•
pull out and empty the overflow tube "A"; try not to spill
the contents inside the machine;
•
Close the water mains cock outside the vending
machine.
•
Loosen the union which fastens the water supply tube
to the solenoid valve in order to release the residual
pressure, then re-tighten.
•
Reinsert the tube "A" in its position, open the water
supply cock and reconnect the electrical power.
BOILER AND AIR-BREAK
The pressure boiler has a capacity of 650cc and it is fitted internally with a 1450W heating element.
The water level in the air-break is controlled by a level sensor.
A vibration pump, which dispenses the amount of water programmed for each selection (controlled by the
volumetric counter), is installed between the boiler and the air-break.
CLEANER / SOFTENER (IF FORESEEN)
The vending machine is not equipped with a cleaner/softener. In case of hard water it is necessary to put a
cleaner/softener that has a capacity according to the machine consumption.
The cleaner/softener (available as an accessory) shall be restored periodically according to the manufacturer's
indications.
FAS International S.r.l. - 60 Via Lago di Vico - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
FAS VICTORIA - ISSUE 00