1. Insert screwdriver from above in the hole on the channel at the desired posi-
tion.
2. Insert separator with screw last in the same channel.
3. Tighten separator with the second screwdriver.
Tightening torque: 0.3 Nm
11.4 Replacing accessories
Fig. 8: Replacing accessories
1. Release screws on old module.
2. Remove old module including screws.
3. Move any existing separators.
4. Place new module on the base plate.
5. Tighten the screws. Respect tightening torques:
rial and
tools.
6. Close off all unused ports.
7. Check for firm fastening.
11.5 Moving separators
1. Remove modules from the base plate.
2. Screw out the push-in fittings.
3. Insert screwdriver into the channel from the front.
4. Release the separator screw by one turn.
5. Insert screwdriver into the channel from the rear and push out the separator.
6. Insert screwdriver from above in the hole on the channel at the desired posi-
tion.
7. Insert separator with screw last in the same channel.
8. Tighten separator with the second screwdriver.
Tightening torque: 0.3 Nm
9. Remount the push-in fittings and modules.
10.Check for firm fastening.
12 Disposal
Improper disposal will lead to pollution of the environment. Furthermore, the
materials can no longer be recycled.
Dispose of the product, the packaging and any escaping operating materials
u
in accordance with the applicable national regulations.
AVENTICS™ XV03 / XV05 | 570365-BAL-AA | English
See g 11.5 Moving
separators.
see g 11.1.2 Required mate-
13 Troubleshooting
13.1 Procedure
Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• All connections. See g 9. Service.
• Settings. See
g 14. Technical
Step 2: Check the product
1. Make sure the system or system part is not under pressure or voltage.
2. Contact manufacturer.
14 Technical data
This section contains an excerpt of the most important technical data. Further
technical data can be found on the product page in the Emerson store.
General
Material of seals
Relative humidity
Ambient temperature
min. ... max.
Ambient temperature for storage
min. ... max.
Nominal diameter of orifice
Assembly
Specifications
Mounting orienta-
Any
tion
Mounting type
Depending on configuration:
• Assembly on mounting plate
• Assembly on DIN rail
• Assembly in control cabinet
Electrics
Specifications
Degree of protection according to
IP65
EN 60529/IEC 529
Supply voltage
24 V DC ±10 %
Power consumption
0.6 W (switching 1.2 W)
Electrical control
Depending on configuration:
• Single wiring
• Parallel wiring via D-Sub
• Bus coupler
Standards and directives complied with
See declaration of conformity.
Pneumatics
Medium
Flow rate
Pneumatic connections
Connection sizes (outputs 2 and 4)
data.
Specifications
NBR, HNBR
95 %, non-condensing
-10 °C ... +50 °C
-25 °C ... +70 °C
XV03
3 mm
XV05
5 mm
Specifications
• Compressed air only
• Non-condensing
• Max. particle size: 40 μm
• Oil content: 0 ... 5 mg/m³
XV03
350 l/min
XV05
900 l/min
Universal thread = combination of BSPP
thread and NPT thread for both push-in
fittings
XV03
Ø 3 mm ... 1/4"
XV05
Ø 4 mm ... 8 mm