4 Transport and storage
4.1 Transporting the product
Hazards during transportation
• Proceed with caution and observe the information on the packaging when un-
loading and transporting the packaged product to the destination.
• Take steps to avoid damage when lifting the product.
4.2 Storing the product
Damage due to incorrect storage
Unfavorable storage conditions can result in corrosion and material deteriora-
tion.
• Only store the product in locations which are dry, cool, and prevent corrosion.
• Keep the product in its packaging until the time of installation.
• Also observe any additional storage information on the product packaging.
Elastomer parts
Pneumatic components typically have elastomer seals that are subject to a con-
stant process of aging.
• Products that have been stored for longer than 2 years have a shorter service
life.
• The aging process can be accelerated by heat and light (UV rays).
If you are unsure about the status of the elastomer seals, Get in touch with our
contact address. See back cover.
Compressed air connections
• Ensure that all compressed air connections are protected against contamina-
tion by protective caps.
• Tape open compressed air connections or provide them with suitable protec-
tive caps.
4.3 Returning the product
• Before returning the product: Get in touch with our contact address. See back
cover.
• Observe the storage conditions until such time as you return the product.
5 Product description
5.1 Brief description
The product is a pneumatic valve system with electrical control. The product is
used for the targeted distribution of stored pressure energy to system compo-
nents.
The product can be divided into integrated pressure zones.
Depending on the configuration, the product can control valves via 1 of the fol-
lowing options:
• Bus coupler
• D-Sub multipole plug
Control via bus coupler
The product can control up to 48 solenoid coils and up to 24 valves.
The product can be diagnosed. See the documentation for the fieldbus module.
Control via D-Sub multipole plug
The product can control up to 42 solenoid coils and up to 42 valves.
5.2 Labeling and identification
Product identification
The ordered product is clearly identified by the material number. The material
number can be found in these locations:
• On the name plate.
AVENTICS™ XV03 / XV05 | 570365-BAL-AA | English
CE mark
This product complies with the Electromagnetic Compatibility (EMC) Di-
rective 2014/30/EU and its amendments. The product is labeled with CE
identification. The declaration of conformity is available on request.
Please provide the material number and serial number for the correspond-
ing products.
Name plate
5
4
3
2
1
Fig. 1: Name plate
1 Supply voltage
3 Degree of protection
5 Valve system number: series - version
- part number of configuration
7 Code of production site
9 Maximum pressure
5.3 Product overview
5.3.1 Product variant XV03
11
10
9
8
7
6
5
4
3
2
Fig. 2: Product variant XV03 with accessories
1 Push-in fitting
3 Ground
5 Port 1 with push-in fitting
7 Through hole
9 Sticker, do not remove (IP protection)
11 Pilot air cover on port X
6
7
8
9
2 QR code for product configurator and
associated documents at Emerson
Store
4 Part number of base plate
6 Date of manufacture
8 Material number of base plate
2 Screw on the side, do not release
4 Port 3 with push-in fitting
6 Port 5 with push-in fitting
8 Port X: Pilot air with push-in fitting
10 Port R: Pilot exhaust with push-in fit-
ting
1
15