5.3.2 Product variant XV05
11
10
9
8
7
6
5
4
Fig. 3: Product variant XV05 without accessories
1 Push-in fitting
3 Ground
5 Port 1 with push-in fitting
7 Port 5 with push-in fitting
9 Sticker, do not remove (IP protection)
11 Pilot air cover on port X
6 Assembly and installation
6.1 Notes on safety
Danger of injury due to leaks
Leaks lead to uncontrolled escape of compressed air and can cause severe in-
juries.
Use a separate tool for screw connections with a thread size of 1/8" for
u
hoses with a diameter of 8 mm. See
als and tools:
Tools.
6.2 Planning
6.2.1 Installation conditions
General requirements
• Make sure that the product is installed in a manner that protects it from all
types of mechanical loads.
Product-specific requirements
• The product contains sensitive electronics.
Recommendation: Handle product with great care.
• Mounting orientation. See
g 14. Technical
• Compressed air specifications. See
• Recommendation: Use oil-free compressed air.
• When using oiled compressed air (not recommended):
– Maximum oil content. See
– Only use oils approved for AVENTICS products.
– Make sure that the oil content remains constant during the entire service
life of the product.
– Never change from oiled to oil-free compressed air.
• Only operate the product with a voltage source and control voltage suitable
for PELV. The voltage source must ensure secure electrical isolation of the op-
erating voltage from the mains in accordance with IEC / EN 60204-1 (accident
prevention).
AVENTICS™ XV03 / XV05 | 570365-BAL-AA | English
3
2
2 Screw on the side, do not release
4 Port 3 with push-in fitting
6 Through hole
8 Port X: Pilot air with push-in fitting
10 Port R: Pilot exhaust with push-in fit-
ting
WARNING
g 6.2.3 Required accessories, materi-
data.
g 14. Technical
data.
g 14. Technical
data.
• Ensure that power packs are equipped with safe isolation in accordance with
EN 61558 and that the power circuits are therefore SELV/PELV power circuits
in accordance with IEC 60364-4-41 (accident protection).
7
• Recommendation: For 5 or more valves and maximum flow, use supply mod-
5
ule and exhaust module. See g 16. Accessories.
4
Ambient conditions
• Let the product acclimatize for a few hours before installation. Otherwise wa-
ter may condense in the housing.
• Make sure that there are no ferromagnetic sources near the product.
6.2.2 Assembly options
6
Mounting options according to configuration
Option
1
Assembly on mounting plate
Assembly on DIN rail
Connection options according to configuration
Option
Parallel wiring via D-Sub
Bus coupler
6.2.3 Required accessories, materials and tools
Select material and tools that are suitable for your product configuration. De-
pending on the configuration, you will need further accessories.
Mounting material
For mounting, you can use your own mounting material or AVENTICS mounting
material. Respect dimensions and tightening torques.
Assembly requires the following material, which is not included in the scope of
delivery. Respect dimensions and tightening torques.
Table 1: Mounting material depending on configuration
Assembly on mounting plate 4x screws M4
Assembly on DIN rail
Tools
• 1x hex key (size 2)
• 1x Torx 5 screwdriver
• 1x Torx 10 screwdriver
• 1x screwdriver PZ1
• For screw connections with a thread size of 1/8" for hoses with a diameter of
8 mm:
1x hexagon socket wrench H6 with length A > 14 mm, if B = 6.35 mm (1/4"),
see
g Fig. 4
Fig. 4: Hexagon socket wrench H6
Add-on-parts
Only use add-on-parts with the specified properties for the connection of your
product (material protection). See
• Only use TU1-F series compressed air tubing with a stiffener sleeve.
Accessory parts
• Only use accessories approved by the manufacturer. See g 16. Accessories.
See
g 6.4.1 Mounting option: Assembly on mounting plate
g 6.4.2 Mounting option: Assembly on DIN rail
See
Documentation of the control
Documentation of the control
XV03
XV05
4x screws M5
1x adapter kit
1x adapter kit
g 14. Technical
data.
16