Connection and start-up
Warning
Read warning notice and instruction manual carefully prior to initial operation and save the information for later use.
8
7
9
11
13
12
1.
Power switch on/off
ON - green (constant light)
Error – red (constant light)
Warning – yellow (constant light)
Standby – green/white (flashing at 5 sec. intervals)
SW update – green/white (flashing at 1 sec. intervals)
2. Mains connection
3. 230V supply for water cooling unit, 4-pin plug
4. CAN connection for water cooling unit, 9-pin plug
5. Connection of USB-plug
6. Gas hose
7. Minus-socket: Connection of welding hose (TIG) or earth clamp (MMA)
8. 7-pole plug - control signals from the TIG torch
9. Connection of shielding gas
10. Plus-socket: Connection of earth clamp (TIG) or electrode holder (MMA)
11. Refill of cooling liquid
12. Cooling liquid level control (Min/Max)
13. Connection of cooling hose, flow (blue)
14. Connection of cooling hose, return (red)
10
Power
14
9
1
2
N
F
4
3
5
6
Gas