L CIRCLE: The detection target is the
large circle area in the center of the
screen.
MANU: The detection target is manually
specified. (☞ Page 23)
AUTO: Dark areas are automatically
masked, and only bright areas are
detected.
Manual detection area setting
Select the divided areas to be masked.
The areas without masking will become the detection areas.
"ELC CONT" screen
** ELC CONT **
AREA
*MANU
PEAK/AVE
RET END
Step 1
Select "MANU" in "AREA" on the "ELC CONT"
screen and press the [SEL] button.
The mask setting screen appears.
→
Step 2
Move the cursor to the target character by
pressing the [g], [h], [e] and [f] buttons,
and press the [SEL] button.
The masked area is displayed in white.
→
....
.... 4
|
P
A
Step 3
Move the cursor to "PEAK/AVE" and use the
[e] or [f] button to adjust the detection level.
When the cursor is moved in the "P" direction,
the peak value (maximum value) is detected.
When the cursor is moved in the "A" direction,
the average value is detected.
Mask setting screen
Note:
•
To cancel a masked area, move the cur-
sor to the area to be canceled and press
the [SEL] button.
To cancel all the masked areas, hold down
the [e] and [f] buttons simultaneously
for 2 seconds or more.
Step 3
Hold down the [FREEZE MENU ] button for 2
seconds or more after completing masking
areas.
The "ELC CONT" screen appears again.
→