FLOW SENSOR ANOMALY ALARM

In case of anomaly of the flow sensor, placed on the primary air
aspiration tube, a blockage signal is send to the stove and right after
the turn-off stage will be immediately activated. (See drawing D86).
If this alarm appears you must contact the technical support service.
11.12

ALARM LIST, PROBLEM AND POSSIBLE SOLUTIONS

Alarm
Description
Code
AL1
BLACK OUT
AL 2
SMOKE PROBE
AL 3
TEMP. SMOKE
BREAKDOWN
AL 4
EXTRACTOR
AL 5
START-UP FAILURE
AL 6
NO PELLET
AL 7
THERMAL ALARM
AL 8
DEPRESSION
AL 9
LACK OF FLOW
AL
FLOWMETER FAILURE
AL b
AUGER ERROR
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Problem
The stove has been temporarily
without electric current.
Problem with the smoke probe.
The smoke temperature is higher
than 270ºC.
Problem with the smoke extractor. Check the extractor electrical connection or replace it.
The fuel does not fall or burn.
There is no fuel in the hopper or it
does not fall inside the burner.
The fuel thermal security
thermostat has shot up.
The combustion chamber is on
depression.
Lack of primary air or installation
not appropriate.
The flow sensor is broken.
The auger spins continuously.
42
ALARM
FLOWMETER
FAILURE
Possible solution
Press button 4 for a few seconds and let the final cleaning stage
to finish. The boiler will come back to the turn-off status.
Check the probe connection or replace it.
Regulate the pellet drop and/or the extractor speed. Verify the
type of fuel that has been used.
Check the geared motor and the resistor way of working. Check
a possible blockage of the endless. Verify that there is fuel in
the tank.
Refill tank. Check the endless working. Check the fuel
characteristics and that it has not become compacted. Clean
the bottom of the hopper.
Restart the thermostat manually. Check the reason why the
temperature is excessive and provoked the overheating (fuel
drop, draw excess, fuel type...)
Verify that the chamber is hermetic: check locks, gaskets... etc.
Check that the gas installation is correct (excess of horizontal
sections, elbow joint, etc). Possible fuel blockage.
Check the primary air inlet. Verify installation (excess of
horizontal section, curves, dirtiness, etc).
Replace the flow sensor.
Verify the electrical connection of the endless.
D86