D27
In the models Eva, Lola and Coral there is another cleaning register:
This register is placed on the left side of the stove, over the smoke extractor
(see drawing D30). To get access to it you have to remove the left side
chamber of the stove.
Do the next operations:
-
Remove the register cover unscrewing the different screws.
-
Clean the ashes deposited on the register, clean the soot deposited.
-
Replace all the pieces and check the staunchness of the register.
8.9
SEASONAL STOPPAGES
If the stove will not be used for a long time it is convenient to keep the fuel
tank empty, such as the screw-type conveyor to avoid the fuel compacting. Clean the stove and the smoke duct, removing the ashes and
other residues, close the stove door. It is recommended to clean the chimney at least once a year. Meanwhile, check the seals because if
they are not in good condition (they do not adjust to the door), they do not guarantee the proper operation of the stove! For this reason, it
would be necessary to change them. If there is humidity in the place where the stove is installed, put absorbent salts inside the equipment.
Protect the internal parts with neutral vaseline in order to keep the appearance overtime.
8.10
MAINTENANCE REVIEW
It is also advisable to check and clean COMPULSORY once a year, the existing ashes registers in the bottom and the top part of the stove.
Your stove has a preventive maintenance notice established after 1200 hours of operation, which will remember you the need of cleaning the
registers of your stove. These operations should be done exclusively by an authorised technician.
This message is not an alarm, but a reminder or warning. Therefore, it will allow you to use the stove while this message is shown in the
display.(see drawing D31).
Please, bear in mind that the stove could need to be cleaned before
this 1200 hours established by default or even after them. This
depends on the quality of the fuel used, the smoke installation, and
the proper regulation of the stove.
In the following table (also pasted on your stove in the fuel tank
cover) you can check the frequency of the maintenance tasks and
who must do it.
CLEANING TASKS
Remove the burner from the chamber and clean the holes with the use of the poker provided. Remove the ash with
a vacuum-cleaner.
Hoover the ashes which are inside the burner place.
Operate the scrapers doing a movement from down to up several times. (**Only models provided of its)
Empty the ash pan or vacuum the ash compartment when necessary.
Vacuum the bottom of the pellet tank when necessary.
Clean the internal of the combustion chamber descale in the walls with a correct vacuum cleaner.
Clean the smoke extractor fan, the whole combustion chamber, pellet tank, whole replacement of the seals and
put again silicone where necessary, smoke duct, reservoirs...
Check all the electronic components (electronic board, display...)
Check all the electrical components (resistance, smoke extractor fan, circulator pump).
10 OPERATION OF THE DISPLAY
10.1
GENERAL INFORMATION OF THE DISPLAY
The display shows information about the stove performance. Once you access to the menu, you will see different screens and configurations
according to the level of access.
Depending on the working mode, the display may have different meanings depending on the position in the screen.
Currently, Bronpi Calefacción has two types of display (according to the model), similar aesthetic but the operation is the same (see drawing
D32).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
D28
32
D29
D30
END HOURS
SERVICE
√
√
√
√
√
√
D31
√
√
√
√
√
√
√
√
√
√
√
√
AIR SERIES