Télécharger Imprimer la page

lamber DSP4-ps Instructions D'emploi page 35

Publicité

Les langues disponibles

Les langues disponibles

It must be furnished with a siphon and have
a right slope.
The machine is provided with a flexible pipe for
the connection with the water-work.
Make sure there are no throttlings along the
pipe.
Carefully comply with any national or regional
regulations in force.
Connencting the drain line:
All plumbing connections must comply with all
applicable national, state and local plumbing
codes.
DETERGENT
REPLACEMENT
CLEANING
OF
PUMP HOSES
Guidelines to be followed when replacing
detergent :
- If you leave the machine without detergent,
crystallization arises due to the formation of air
bubbles
- Set up again detergent pump hose anytime you
use a new detergent
- The whole system consists of a container,
dosage hoses and detergent pump hoses and
must be cleaned before using a new detergent.
- Call on your authorized technical assistance to
fulfil the necessary operations to obtain a good
cleaning result.
-
You are recommended to proceed with the
cleaning of the dosage hoses and the detergent
pump with water once a month.
Failure to comply with these guidelines will
render
this
guarantee
disclaims any liability for consequential
damage on the product.
You can clean yourself the dosage hoses and the
detergent pump with water.
Guidelines:
A
-
Disconnect the suction hose from the
detergent can.
AND
THE
DETERGENT
invalid.
Lamber
B
-
Connect the suction hose to a new water
recipient.
C
-
Switch the Self-cleaning cycle on (see
paragraph page 12)
D
– Once self-cleaning is finished, connect the
suction hose to the detergent can.
WARNING!
and chemical
When using chemical products you must wear
personnal protection equipment, gloves and
protection glasses. Do not mix different
detergents together.
WARNING!
the peristaltic pumps suction pipe cod.
0500094 (see draw)
35
: Respect security
dosage guidelines.
: Replace every 6 months