3.6 Rear panel
1
Gas fitting
2
Signal cable input (cable bundle)
3
Power cable input (cable bundle)
4
Positive power socket (MMA)
5
Cooling liquid inlet/outlet
6
Attachment for wire holder tube
3.7 Sockets panel
1
Torch fitting
Permits connection of the MIG torch.
2
External devices (Push/Pull)
3
Torch button connection
4
Cooling liquid connection
4 ACCESSORIES
4.1 General
Operation of the remote control is activated when connected
to the Selco power sources. This connection can be made also
with the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 180 remote control
This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".
4.4 RC 190 remote control
1
Allows continuous adjustment of the wire feed speed.
Allows the regulation of the welding current.
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
41