WF...RapiDeep Exclusive
WF...RapiDeep Steel
14
Programs (WF...Exclusive, RapiDeep Exclusive,
RapiDeep Steel)
Allows the storage and management of 64 welding pro-
grams which can be personalised by the operator.
Program storage
Enter the "program storage" menu by pressing button
(14) for at least 1 second.
Select the required program (or the empty memory) by
rotating the encoder.
Confirm the operation by pressing button-encoder (6).
Program retrieval
Retrieve the 1st program available by pressing button (14).
Select the required program by pressing button (14).
Select the required program by rotating the encoder.
Only the memories location occupied by a program
are retrieved, while the empty ones are automatically
skipped.
15
Wire feed
Allows the manual wire feed without gas flow and with-
out the wire live.
Allows the insertion of the wire into the torch sheath
during the welding preparation phases.
35