2.1
WATER
SPECIFICATIONS
Monitoring of water recipe to keep it within required
levels and maintenance of filtration system is the
user's responsibility.
Failing to meet and maintain water at the following
levels will void the entire warranty:
• total hardness 50-60 ppm (parts per million).
• water line pressure between 2 – 4bar and water
to be cold.
• min flow rate: 200 l/hr.
• filtration level below 1.0 micron.
• tds (total dissolved solids) level between 50 – 250
ppm.
• alkalinity level between 10 – 150 ppm.
• chlorine level less than 0.50 mg/l.
• Ph level between 6.5 and 8.5.
2.2
ELECTRICAL
SPECIFICATIONS
RISK OF SHORT CIRCUITS
The machine must always be protected by an
automatic omnipolar switch of suitable power
with contact openings that permits the complete
disconnection under conditions of overload cat-
egory III.
Simonelli Group is not liable for any damage to
people or objects due to not observing current
security measures.
Prior to connecting the machine to the electrical mains,
assess that the voltage shown on the machine's data
plate corresponds with that of the mains.
NOTE:
At the start of the day's activities and in
any case, if there are any pauses of more
than 8 hours, then it is necessary to change
100% of the water in the circuits, using the
relevant dispensers.
NOTE:
In case of use where service is continuous,
make the above changes at least once a
week.
34
CAUTION
3.
ADJUSTMENTS
TO BE MADE BY
A QUALIFIED
TECHNICIAN ONLY
The adjustments listed here below must ONLY
be performed by a Specialist Technical Engineer.
Simonelli Group cannot be held liable for any
damage to persons or property arising from fail-
ure to observe the safety instructions supplied in
this manual.
ELECTRIC SHOCK HAZARD
Before performing any operation, the specialist
technical engineer must first switch off the main
switch off and unplug the machine.
3.1
FILLING BOILER
MANUALLY
All models
gauge to keep the water level inside the boiler
constant.
When using the machine for the first time, it is advis-
able to fill the boiler by hand to avoid damaging
the electrical resistor and turning on the electronic
protection.
If this should happen, just turn the machine off
and then start it up again to complete its loading
procedure (see chapter "MACHINE FUNCTIONS
MESSAGE – LEVEL ERROR").
To fill the boiler manually for the first time, proceed
as follows:
• remove the worktop grid;
• remove the sheet metal guard by unscrewing the
four screws at the sides (A), as illustrated in the
following figure;
A
EN
CAUTION
CAUTION
are equipped with a level
Fig. 6

Publicité

loading