EN
fitted with economiser).
5. Disenabling the cup warmer
6. Restoring default settings.
1. Enabling the pump during levelling.
Use the espresso key
during levelling:
if the key
is lit, the pump is enabled together with
the level; if it is switched off, the pump is not enabled
with the level function.
2. Enabling the software block to enter the dose
programming function.
Use the long coffee key
block to programme doses (key lit) or to de-activate
the block (key off).
3. Adjusting keypad brightness.
The 2 long coffees key
used to choose the key brightness setting from 5
pre-set levels.
Use the
, key, which will flash, to change the
level, lowering it to minimum or returning it to maxi-
mum.
4. Enabling the hot water pump (machines fitted
with economiser only).
Use the hot water key
on while hot water is being delivered.
If the
key is lit, the pump will switch on while hot
water is being delivered; if it is switched off, the pump
will not switch on.
5. Starting the pump with steam (only for machine
models with timed steam or autosteam func-
tions).
The steam key
is used to set the pump to start
while steam is being dispensed.
If the key
is lit, the pump will start while steam is
being dispensed; if the key is not switched on, then
the pump will not start.
to set pump enabling
to enable a software
of the second group is
to set the pump to switch
5.9
AUTOMATIC GROUP
CLEANING CYCLE
To start the automatic cleaning mode, the machine
must first be switched off and then back on again
while holding down the hot water
coffee from group 2
At the end of the Flash-test, the
and the single long coffee key
begin to flash.
Press the
key to start the washing cycle for the
relevant group.
Once the washing cycle has been completed, it is
possible to perform a rinse cycle for the same group
by pressing the
key again.
To perform the rinse cycle at a later time, switch off
the machine and the card will store any cleaning
cycles that need to be completed in its memory. In
fact, the next time that the machine is switched on,
the machine card will automatically open the group
cleaning status without it being necessary to press
the
and
keys.
Hold down the
and
exit the cleaning mode in the event that there are
no cycles to be completed. For incomplete cycles,
the
keys of the groups that require rinsing will
continue to flash.
Hold down the
and
to force exit from the cleaning mode, resetting all
information about rinse cycles still to be completed.
When a cleaning cycle is complete, the
the group will switch off.
If there are no more rinse cycles to be performed, the
card will exit the cleaning mode.
and one low
during the initial Lamp-test.
and
keys
of all groups will
keys for 2 seconds to
keys for 2 seconds more
key for
41