Every installation must provide for an easily accessible technical space for periodical maintenance.
The stove is provided with 4 adjustable feet to facilitate positioning on not perfectly flat floors. To adjust the height,
tilt the stove slightly and turn the feet as required.
The stove is supplied with the ambient sensor fixed through a wrapper on the back of the stove; we recommend to
remove the wrapper and to locate the sensor in the best position possible as to improve the temperature registration
in accordance with the ambient context and the length of the cable.
As for temperature registration done at a certain distance we reccomend to install the ambient thermostat/ambient
programming clock-thermostat – see. par.4.8.
- The stove cannot be installed in bedrooms, bathrooms and in general in rooms where
another heating unit is already installed without an independent air inflow.
- With wooden floors, install a floor protection base in conformity with the current regulations.
- In case of fire, shut down the stove, promptly call the fire department, and avoid continual attempts to extinguish it.
- Do not install the stove in places with an explosive atmosphere.
2.3 Air inlet
The attack suction or air intake of the stove is placed rearwardly and is of circular cross section with a diameter of
50 mm. In the room where the stove is installed it must pour a quantity of air at least equal to that required for
combustion; for this reason the combustion air must ensure a flow of air, clean and free of polluting elements, to
satisfy a regular combustion at maximum power without any hindrance or obstruction of the passage section. The
devices ponds must be taken throughout the combustion air from the outside environment and can be installed in
homes or well insulated high energy efficiency.
For it to be soddisfattii requirements of tightness the combustion air inlet must be connected:
A - directly to the outside of the dwelling with an appropriate tube minimum internal diameter of 50 mm and a
maximum length of 1.5 m fitted at the ends of a suitable grid wind protection (curve downwards + insect mesh) and
positioned so to avoid the obstruction;
B - on the pickup tube air combined with the exhaust pipe.
-
It is recommended to connect the unit to the external air intake pipes and fittings that guarantee
tightness to meet the requirements for the installation of a device
- With the installation of B is an increase in temperature of the exhaust fumes therefore we recommend
to reset the parameters of the stove and check the
Antiwind
grille
Flue
Flue connection
Inspection door on
flue
Air inlet
min. 100 cm²
T union with
inspection cap
Floor protection base
pool.
operation.
33
A = 200 mm
B = 200 mm
C = 1000 mm
D = 200 mm
SWING