Télécharger Imprimer la page

Bosch ACS 663 Notice Originale page 63

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 80
i
Select
to print the overview.
Select
to return to the Main Menu.
21. The A/C system of the vehicle at this point is ready
for use.
6.7
Automatic function
WARNING: to prevent injuries while
working with the refrigerant, read and
follow the instructions and warnings in this
manual, and wear protective clothing, such
as safety glasses and gloves.
The automatic function allows the user to program an
automatic recovery, vacuum, leak check, and/or charge
sequence.
i
The maintenance parameters (filling quantity,
refrigerant type and new oil) can be acquired
from the database and used during the "automatic
function".
!
In vehicles with only one service connection, it is
necessary to follow the procedure recommended by
the vehicle manufacturer.
!
The charging function for vehicles equipped with
a single service connection must be performed
manually, following the procedures in the vehicle
manufacturer's maintenance manual.
!
The maintenance parameters (filling quantity,
refrigerant type and new oil) are given in the vehicle
operating instructions or in the repair manual and
must be respected.
i
The amount of oil extracted during the recovery
process is injected automatically before the charging
cycle.
!
Before performing any oil or UV dye injection make
sure a proper quantity is available into the respective
bottle.
1. Call up the Main Menu.
2. Select
.
3. Enter the service data and select
vehicle data through the database. Confirm with
(see chapter 6.1).
4. Enter the vacuum time.
5. Select the "vacuum test" with the Down arrow
button and set
to enable or disable the function.
Robert Bosch GmbH
6. Enter the quantity of refrigerant to be charged with
the numeric keypad.
7. Select the "type of charge" with the Down arrow
button and set with
charge the vehicle (high pressure side, low pressure
side or both sides).
8. Select
9. Select
to perform the oil injection, go directly to phase 13
displaying.
10. Enter the amount of oil to be added to the amount
recovered from the A/C system with the numeric
keypad.
11. Select the "oil type" with the Down arrow button
and set with
12. Type the measured ambient temperature and set the
viscosity of oil being used.
i
Make sure of entered values correctness in order to
guarantee the injection accuracy.
13. Select
14. Select
i
The UV dye injection (timed) is performed with
a fixed dose of about 7.5 ml. However it can be
adjusted by double or half amount by "Dye injection
adjust" in the Settings Menu.
15. Select
16. ACS 663 displays a dedicated message that asks to
the operator whether to perform the hoses flushing.
« Select
hoses flushing.
i
Follow the on-screen instructions to perform the
hoses flushing procedure.
17. When the message appears, connect both service
hoses to the vehicle service connections and open
the valves of the service hoses turning the ring nuts
clockwise.
18. Select
19. Follow the on-screen instructions while the ACS 663
performs the automatic cycle.
20. When the message appears, close the service hose
connections turning the ring nuts counter-clockwise.
Disconnect the service hoses from the A/C system
and connect them to the station flushing connections.
21. Select
22. ACS 663 displays, at the end of the hoses cleaning,
to set the
a dedicated message that indicates to the operator
the procedures to be performed to start the
pressures test (see chapter "Pressures test").
« Select
pressures test.
Instructions for use | ACS 663 | 63
the hoses to be used to
to continue.
to enable the oil injection. If you set not
the oil to be charged (PAG or POE).
to continue.
to enable the UV dye injection.
to continue.
to proceed or
not to perform the
to start the automatic procedure.
to start the hoses cleaning.
to proceed or
not to perform the
SP00D00616
en
|
2019-11-08

Publicité

loading