2.3.2 Liquid temperature
32-104 °F (0-40 °C).
For non-explosion-proof pumps, a temperature of
up to 140 °F (60 °C) is permissible for short
periods (maximum 3 minutes).
2.3.3 Ambient temperature
32 °F to +104 °F (0 to +40 °C).
Explosion-proof pumps must never
FM
pump liquids at a temperature higher
than +104 °F (+40 °C).
2.3.4 Density and viscosity of pumped liquid
When pumping liquids with a density and/or a
kinematic viscosity higher than water, use motors
with correspondingly higher outputs.
Keep a minimum flow velocity to
avoid sedimentation in the piping
system.
Flow
Recommended flow velocities:
velocity
in vertical pipes: 2.3 ft/s (0.7 m/s)
in horizontal pipes: 3.3 ft/s (1.0
m/s).
Free
2" - 4" (50-100 mm), depending on
spherical
pump size.
passage
Operating
Maximum 20 starts per hour.
mode
Related information
7.2 Operating mode
2.4 Identification
2.4.1 Nameplate
The nameplate states the operating data and
approvals applying to the pump. The nameplate is
fitted to the side of the stator housing close to the
cable entry.
Fix the extra nameplate supplied with the pump to
the cable end in the controller.
24
26
27
23
FM23US0056
FM23CA0041X
1
2
3
4
7
22
7
8
5
6
17
18
Nameplate
20
25
21
9
28
10
11
13
14
16
19
15
12
Pos. Description
1
Type designation
2
Product number
3
Max. head [ft]
4
Maximum installation depth [ft]
5
Number of phases
6
Frequency [Hz]
7
Rated speed [min
8
Motor input (P1) / output (P2) power [hp]
9
Production code (year and week)
10
Max. flow rate [GPM]
11
Max. liquid temperature [°F]
12
Insulation class
13
Power factor
14
Rated current [A], delta connection
15
Rated voltage [V], delta connection
16
Rated current [A], star connection
17
Rated voltage [V], star connection
18
Enclosure class
19
Net weight [lb]
20
US marking of explosion protection
21
CA marking of explosion protection
22
Mark of Approved body
23
Country of production
24
Installation and operating instructions
25
Thermal protection
US Explosion protection certificate
26
number
CA Explosion protection certificate
27
number
28
Ambient temperature
-1
]