5-3. Tipping
5-4. Preparing Unit For Operation
1
2
OM-244785 Page 14
5
4
!
Do not move or operate unit
where it could tip.
!
Do not move unit by pulling
on extraction hose or equip-
ment may tip. Use handle on
fume extractor to move unit
!
Do not use this equipment to
support personnel, large
tools, or other material.
!
Do not use the fume extraction
equipment unless you are sure
it is correctly assembled and
working properly.
1
Connection Port
2
Collection Hose
6
3
Nozzle (Optional) − Not Shown
4
Caster w/Brake
5
Latch
6
115 Volt, 15 Amp AC Grounded
Receptacle
7
Input Power Plug
Insert the stub end of the collection
hose into the connection port. Be sure
the hose is securely installed.
7
Connect optional nozzle to other end
of collection hose.
Verify all eight latches are closed and
provide a secure attachment.
Lock caster brackets to keep fume
extractor in desired location.
Connect power cord to power supply.
A 115 volt AC, 15 amp individual
branch circuit protected by time delay
fuses or circuit breaker is required.
.
Set Air Flow control at level 6 be-
fore starting unit. After unit starts,
reduce air flow to desired level
(see Section 6-1).
Select 12 AWG extension cord for
distances up to 50 ft (15 m) or 10
AWG extension cord for distances up
100 ft (30 m).
245 353