Télécharger Imprimer la page

Saf-Fro DIGIWAVE III Instructions D'utilisation Et D'entretien page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
Manual commands
Manual wire advance speed(m/min)
Purge gas time
User management
Page 27
Import/Export USB – Ethernet
Page 26
Counters
Page 37
Network
Network Status
Network Configuration
Network Hosts
6.2. AUTOMATION INTERFACE DECRIPTION
Configuration>Installation>Général >Automatisation
The N1 interface distinguishes the following signals:
SIGNAL
1
DCY*
CLOSE TO START WELDING
2
RI**
CLOSE WHEN CURRENT IS DETECTED
CLOSE WHEN THERE IS NO DETECTED DEFAULT ON
3
DEFAUT
THE POWER SOURCE
* Cycle Departure ** Welding current detection
Installation configuration in automation level N1 
When the N1 automation mode is enabled:
MMA and TIG menus are no longer available
A specific page to the automation level N1 is added to the MIG menu SETUP
ARC START (RI) and START CYCLE (DCY) signals are enabled
Only specific automatic welding cycles are available
You can activate the automation N1 and the mode of functioning of the RI output in the menu: Configuration>Installation>General.
The choice of active level for DEFAULT signal is defined in the menu: Configuration>Installation>Default.
DIGIWAVE III
Setting of the default wire speed by pressing the manual wire advance speed button on the
Wire Feeder.
Setting of the opening time of the gas valve when the user presses the gas purge button on
the Wire Feeder.
Setting of the network status 5.
Network configuration: DHCP or manual entry.
Management of the network hosts.
Figure: Wiring for N1 interface on connector J2
         
SENS
TYPE
REMARKS
INPUT
TOR
OPTO-COUPLER, 5 V – 5 MA
OUTPUT
TOR
RELAY CONTACT, 2 A – 48 V
OUTPUT
TOR
RELAY CONTACT, 2 A – 48 V
DCY: Cycle Departure
0V
RI: Welding current detection
Default
Shared Default &RI
Ground
EN
33

Publicité

loading