STEP 3 :
Name of the power source.
This is the name used for identifying the machine when installations communicate.
Please check that different installation have different names. During an export to an external storage device, the name of the directory created is
composed of the power source name and the date.
STEP 4 :
Configuration du groupe de refroidissement s'il est utilisé. (paragraphe 6.1)
HARNESS CALIBRATION
Harnesses calibration is imperative to weld with a good quality.
The calibration is to be re-done, in case of polarity change, or change of one of these following components:
torch
harness
ground cable
position of the clip of the ground cable
Access in the menu: MIG > SETUP > Harness calibration
Automatic Calibration: (Only available in MIG). Follow the instructions on the screen.
During this operation, a current of 400A for 1 second is generated. It is imperative then to wear the correct protection equipment required for
welding during this operation, in particular, protection glasses.
3.2. FIRST SETTING FOR EASY ACCESS TO WELD
PRESENTATION OF THE MIG WELDING TUNING PAGE
Welding Programs Management
DIGIWAVE III
/
Access Zone 1 or Zone 11
Change in the characters column
Add or suppression of a character
Save
WARNING
Parameters selection
Parameters value selection
Validation
Welding Cycle Management
EN
Access to the
Setup
information window