IBM Confidential
contenant suffisamment de garniture pour protéger la cartouche (en amortissant les chocs) et l'empêcher
de bouger dans l'emballage.
Le Tableau 65, à la page 239 informe sur les conditions d'utilisation, de stockage et d'expédition des
cartouches de bande LTO Ultrium.
Tableau 65. Caractéristiques de température et d'humidité de la cartouche de bande
Mode
Environnement
recommandé
Environnement autorisé
Température
d'endommagement de la
bande permanente locale
2
Transport maritime
Remarques :
1. Selon la spécification de format de bande LTO U932 , ce mode est appelé température de stockage à court
terme et la plage de températures est comprise entre 16°C et 35°C.
2. Une température de la bande locale supérieure à 52°C peut endommager la bande de façon permanente.
Disposing of tape cartridges
Current rules about the appropriate disposal of tape cartridges.
Under the current rules of the US Environmental Protection Agency (EPA), regulation 40CFR261, the LTO
Ultrium Tape Cartridge is classified as non-hazardous waste. As such, it might be disposed of in the same
way as normal office trash. These regulations are amended from time to time, and you must review them
at the time of disposal.
If your local, state, country (non-US), or regional regulations are more restrictive than EPA 40CFR261, you
must review them before you dispose of a cartridge. Contact your account representative for information
about the materials that are in the cartridge.
If a tape cartridge must be disposed of in a secure manner, you can erase the data on the cartridge with
a high-energy ac degausser (use a minimum of 4000 oersted peak field over the entire space that the
cartridge occupies). The tape must make two passes through the field at 90 degree orientation change
for each pass to achieve complete erasure. Some commercial degaussers have two magnetic field regions
offset 90 degrees from each other to accomplish complete erasure in one pass for higher throughput.
Degaussing makes the cartridge unusable.
If you burn the cartridge and tape, ensure that the incineration complies with all applicable regulations.
Humidité relative (pas de
1
Température
16°C - 25°C
16°C - 32°C
>52°C
25°C - 49°C
Température du point de
condensation)
20% à 50%
20% à 80%
S/O
5% à 80%
Annexe F. Support LTO 239
rosée
22°C
22°C
S/O
26°C