13. Wiring
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
- check that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture,
installation, use, and maintenance foreseen by the norms in force in the country where
the cabinet is installed.
To ensure normal operation, the maximum variation of the voltage must range between
+/- 6% of the nominal value.
Customer
Liability
Installer
ARNEG
Power
power supply
- has wires with suitable cross section
- is protected against over-current and dispersions toward earth in
i
Automatic
safety switches
Cabinets with
built-in unit
46
provide a power line to the cabinet connection point.
provide the anchoring devices for all the wires in input
and output to/from the cabinet.
ARNEG S.p.A. denies all liability with respect to the user or
third parties for:
- damages caused by failures or malfunction of the
systems installed upstream of the cabinet
- damages to the cabinet due to causes arising directly
from malfunction of the electrical system
the supply lines of the electric energy should meet the requirements of
power consumption of the cabinet(cap.9.).
check that the power line:
accordance with the rules in force
for the power supply lines measuring more than 4-5 m, increase the
section of the cables appropriately.
The replacement of the damaged power cord is reserved to the
manufacturer or a body authorized by the same.
protect the upstream cabinets with omnipolar circuit breakers with
suitable characteristics that will also have the function of master switches
for cutting off the line
instruct the operator on the position of the switches to be reached
quickly in case of EMERGENCY
DANGER! Live parts. Short circuit. Emergency.
The circuit breakers must not open the circuit on neutral point
without opening it simultaneously on phases and, however, must
allow complete cut off in overvoltage conditions category III
the cabinets are preset for plug connection (NOT SUPPLIED)
install a suitable plug of suitable capacity, compliant with regulations in
force and observe the safety rules:
yellow-green = ground / light blue = neutral / brown-black = phase
the electrical cable must be stretched to avoid damaging it or
endangering people
DANGER! Live parts. Short circuit. Emergency.
Do not use sockets already connected to other users, nor reducers,
pins or multiple sockets.
05060156 00 22/10/2014