Instructions For Use Machine Light ABLTL 1

Connection

NOTICE
Damage caused by wrong con-
nection!
Wrong connection may result in
the light being damaged or de-
stroyed.
¾ Operate the light with the ope-
rating units proposed by the
manufacturer only.
¾ Connect the light only when the
operating device is off!
¾ Install the switch always in the
primary electric circuit (see
fig. 14)!
¾ Connection only by a skilled
electrician!
¾ The operating unit must be
positioned in accordance with
its type of protection.
Fig. 14
Operating
Unit
Connection
Important Information
See connection diagrams on page
31.
Depending on the mains voltage
and the selected operating cur-
rent, different operating units are
suitable.
Suitable operating units can be
found in the Appendix (page 30).
Connect the light as shown on
page 31.
Two versions of the the Waldmann
operating unit are available, which
have different operating currents.
Note: Higher operating current
means higher light yield and short-
er useful life.