Télécharger Imprimer la page

PRESIDENT GEORGE FCC Manuel D'utilisation page 14

Publicité

Les langues disponibles

Les langues disponibles

10) PA SETTING
select
This function allows to
the operating mode of Public Address.
Long Press PUSH key (4) to
enter
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the PA SETTING menu.
2.
Press PUSH key (4) to
validate.
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
to
select
the operating mode of the PA : I n, OF or PA.
4.
Short press PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press PTT key (18) to
pears from the display.
5.
If no key is pressed, the unit
exits
from the display.
I n: the modulation of the microphone is transmitted to the external loud-
speaker connected to jack PA.SP. (D). The received signal is transmitted to
the internal loudspeaker [or external optional loudspeaker connected to
jack EXT.SP (E). "PA" blinks alternately with the modulation mode (AM or FM).
OF: The reception is no more functional. Only the modulation of the micro-
phone is transmitted to the Public Address loudspeaker connected to jack
PA.SP. (D). PA and level of the
PA: the modulation of the microphone and the received signal are transmit-
ted to the Public Address loudspeaker connected to jack PA.SP. (D). "PA"
blinks alternately with the modulation mode (AM or FM).
Turn the VOL knob (1) to
adjust
Default PA setting is I n.
See § PA (Public Address) page 8.
11) MICROPHONE TYPE
PRESIDENT GEORGE FCC can be used with both a PRESIDENT electret and
dynamic 6-pin microphone (see microphone wiring on page 59). When
the unit is turned on, the microphone type is displayed briefly.
Long Press PUSH key (4) to
enter
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the
menu.
2.
Press PUSH key (4) to
validate.
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
select
to
the microphone type EL (electret) or dy (dynamic).
4.
Short press the PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press the PTT key (18) to
the MENU.
is displayed.
The current value blinks on the display.
validate
and
exit
the MENU.
MENU after 10 seconds.
disappears
PA
are displayed.
the audio level of the mode PA.
the MENU.
is displayed.
The current value blinks on the display.
validate
and
exit
the MENU.
disappears from the display.
5.
If no key is pressed, the unit
from the display.
Microphone type default is EL (electret).
12) SWR CALIBRATION
This function allows you to
Long Press PUSH key (4) to
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
disap-
select
the
menu.
2.
Press PUSH key (4) to confirm. The radio automatically switches to
without pressing the PTT switch (18) and calibration begins. Calibration time
is 5 minutes maximum. A countdown is done in the display.
3.
Adjust the antenna.
-
The beep* is continuous when the SWR value is 1. 0 . The space between the
beeps becomes larger and larger as the SWR value moves away from1. 0 .
The volume of the beep is adjustable with VOL knob (1).
-
-
The display shows the SWR value, for example 2. 5 .
4.
Press the PTT switch (18) to
*Check that the beep volume is set to a suitable level.
See ADJUSTMENT OF SWR page 6.
13) NRC SET
The NRC filter can be set independently in transmission ( ) as in reception
( ).
Long Press PUSH key (4) to
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the
on the display.
2.
Press the PUSH key (4) to confirm. The parameter blinks, X or X .
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
to
select
X (recepetion) or X (transmission).
4.
Press PUSH key (4) to confirm. The value of the filter blinks.
5.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
change
to
the value from 01 to 05.
6.
Short press PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press PTT key (18) to
pears from the display.
The default value are 01 (transmision) and 01 (reception)
See the § NRC page 10 to
14
exits
MENU after 10 seconds.
adjust
the SWR by beeping.
enter
the MENU.
is displayed.
exit
SWR CALIBRATION.
enter
the MENU.
is displayed.
menu. The last parameter used and its value appears
validate
and
exit
the MENU.
activate/deactivate
the function.
disappears
TX
mode
disap-