*6 roger tones for ROGER BEEP.
Default ROGER BEEP is OF.
6) INDIC
Use this function to select the information to be displayed.
In RX mode:
Frequency and voltage are displayed continuously.
In TX mode:
Long Press PUSH key (4) to
enter
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the INDIC menu.
2.
Press PUSH key (4) to
validate.
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone to
select
the function to be displayed. FREQUENCY ~ SWR ~ TOT is displayed
alternately. Each time the PTT is pressed, the display indicates the voltage
and function selected..
4.
Short press PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press the PTT key (18) to
disappears from the display.
5.
exits
If no key is pressed, the unit
from the display.
7) SCAN MODE
Allows to
select
the MODE of SCAN.
Long Press PUSH key (4) to
enter
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the SCAN MODE menu.
2.
Press PUSH key (4) to
validate.
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
to
select
the mode CH or NE.
4.
Short press PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press PTT key (18) to
pears from the display.
5.
exits
If no key is pressed, the unit
from the display.
"CH" means that the station scans all 40 channels of the active frequency
band.
"nE" means that the station scans memorized and priority channels only.
Default mode is: CH.
the MENU.
is displayed.
The current value blinks on the display.
validate
and
exit
the MENU.
MENU after 10 seconds.
disappears
the MENU.
is displayed.
The current value blinks on the display.
validate
and
exit
the MENU.
MENU after 10 seconds.
disappears
8) SCAN TYPE
Allows to
select
the TYPE of SCAN.
Long Press PUSH key (4) to
1.
Turn the CH rotary knob (4) or use UP/DN keys (19) on the microphone to
select
the SCAN TYPE menu.
2.
Press PUSH key (4) to
3.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
select
to
the scan type sq or t 1.
4.
Short press the PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press the PTT key (18) to
disappears from the display.
5.
If no key is pressed, the unit
from the display.
"
"means scanning stops when busy channel is founded.
"t 1" means scanning stops when busy channel is founded and return to
scan after 5 seconds.
Type default value is : 59.
9) SCAN SKIP
This function allows to
memory.
1.
Select a channel
2.
Long Press PUSH key (4) to
3.
Turn the CH rotary knob (6) or use UP/DN keys (13) on the microphone to
select
the
4.
Press PUSH key (4) to
5.
Turn the CH rotary knob (4) or use the UP/DN keys (19) on the microphone
to
alternate
between On and OF.
6.
Short press PUSH key (4) to validate. a) Return to the point 1 to set another
menu or b) Short press PTT key (18) to
pears from the display.
7.
If no key is pressed, the unit
from the display.
disap-
On memorize the current channel into the SCAN SKIP memory. When a
channel is stored in the memory,
channel number.
OF erase the current channel from the SCAN SKIP memory,
from the display.
See § SKIP on page 9.
13
enter
the MENU.
is displayed.
validate.
The current value blinks on the display.
validate
and
exits
MENU after 10 seconds.
memorize/erase
a channel form the SCAN SKIP
enter
the MENU.
is displayed.
menu.
validate.
The current value blinks on the display.
validate
exit
the MENU.
and
exits
MENU after 10 seconds.
appears on the display close to the
exit
the MENU.
disappears
disap-
disappears