13. Model code
Series no.
EN
Type of connection, mechanical
9
= G 1/4" female thread to DIN 3852, Form X
Display
1
= 4 digit bar
2
= 4 digit psi
Accuracy
P
= 0.5 %
N
= 1 %
Pressure ranges in bar
016, 040, 100, 250, 400, 600
Modification number
000 = standard
14. Accessories
14.1. ACCESSORIES SUPPLIED WITH THE UNIT
 PG 11 cable glands
 4 mounting screws M5 x 20 mm
14.2. OTHER ACCESSORIES
 Mounting kit (4 vibration mounts, 4 screws M5 x 6 mm)