Télécharger Imprimer la page

HYDAC ELECTRONIC EDS 1700 Mode D'emploi page 35

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Setting
Primary display (Primary)
Display value which should remain
remain permanently in the display:
"ACT.":
"S.P.1" .. "S.P.4":
"MAX":
Display filter (Display)
"SLOW":
display reacts slowly to pressure
fluctuations.
"MED.": display reacts normally to pressure
fluctuations.
"FAST": display reacts quickly to pressure
fluctuations.
Determining the display range
(RANGE)
"BAR":
The pressure is displayed in bar.
"PSI":
The pressure is displayed in psi.
"FREE": The display range can be defined
by the user. If this setting is
selected, then decimal places
and upper and lower display range
must be set. (see below)
Example: If the display range is
Application: Display of other units
current pressure
switching point 1..4
maximum value
changed to 0..215.5,
the display value 215.5
corresponds to the
nominal pressure of the
unit.
which are proportional
to the pressure
e.g. KN, kg, ...
Display
Setting
range
ACT/
S.P.1..
S.P.4/
MAX
SLOW/
FAST
BAR/
PSI/
FREE
Pre-
setting
ACT.
EN
MED.
MED./
BAR
29

Publicité

loading