- Community: a set of clocks defined by the user.
It is important to give all clocks on the network the same Community name.
- Synchronisation failure: this setting is used to detect synchronisation discrepancies with the
master clock (Sigma type) or the time server (Netsilon type).
Multicast: alarm triggered when the multicast synchronisation has been absent for over an hour.
Unicast: alarm triggered when the unicast synchronisation has been absent for three times the
duration of the poll (periodicity) and at least one hour (allowing for the NTP server maintenance).
- Hands position control: this setting is used to detect hands position failures.
- Shock: inactive parameter.
- Open case: inactive parameter.
- Lighting failure: when checked, this setting is used to detect a failure with the clock lighting.
- Battery failure: when checked, this setting is used to detect a low battery level.
- Battery maintenance: this setting is used to define the lifespan of the battery (from 20 months to
50 months).
- Power failure: when checked, this setting is used to detect a power supply failure.
When the clock has a battery, the alarm is sent after a set period (configurable) without
mains power supply. When the clock does not have a battery, the alarm is sent when the clock is
rebooted.
- Temperature: inactive parameter.
- Periodic Status: when enabling this setting, an alarm is issued periodically (configurable
duration) to indicate to the SNMP manager that it is still "alive". The alarm corresponds to the
status of the clock.
Information: the information reported is minor and do not require the visit of a service
technician to correct the fault.
Warning: the errors or faults reported are serious and require the visit of a service
technician to correct the fault.
Critical: the errors or faults reported are serious and require prompt visit of a service
technician to correct the fault.
The Save button saves the configuration data entered.
The Send status trap button is used to send a status trap to all the configured SNMP managers to
ensure that supervision is configured correctly.