10.3 Extended functions
10.3.1 Setting of the delay time for switching outputs
► Change to [EF]�
► Select a parameter with the "up" or "down" button: [dSx] = switch-on
delay; [drx] = switch-off delay�
► Set the parameter value with [Enter]:
> Set parameter value is displayed�
► Keep the "up" or "down" button pressed for at least 3 s�
> Parameter value flashes�
► Set the parameter value by means of the "up" or "down" button�
Setting range [s]: 0 / 0�1���5 s in steps of 0�1 s
(0 = delay time is not active)
► Confirm with [ENTER]�
10.3.2 Setting of the fault suppression time for switching outputs
► Change to [EF]�
► Select the parameter [dFo] with the "up" or "down" button:
► Set the parameter value with [Enter]:
> Set parameter value is displayed�
► Keep the "up" or "down" button pressed for at least 3 s�
► Parameter value flashes�
► Set the parameter value by means of the "up" or "down" button�
Setting range [s]: 0 / 0�1���5 s in steps of 0�1 s
► Confirm with [ENTER]�
10.3.3 Reset of all parameters to factory setting
► Change to [EF]�
► Select [rES] with the "up" or "down" button, then press [Enter]�
> [ rE] is displayed�
► Keep the "up" or "down" button pressed until [---] is displayed�
> All parameters are reset to factory setting�
11 IO-Link
11.1 General information
This unit has an IO-Link communication interface which requires an IO-Link-
capable module (IO-Link master) for operation�
The IO-Link interface enables direct access to the sensor values and parameters
and provides the possibility to set the parameters of the unit during operation�
In addition, communication is possible via a point-to-point connection with a USB
adapter cable�
You will find more detailed information about IO-Link at www�autosen�com�