9 Operating modes
9.1 Run mode
The run mode is the normal operating mode�
After power on the unit is in the run mode� It carries out its monitoring function and
generates output signals according to the set parameters�
The display indicates the current distance or the object reflectivity, the yellow
LEDs signal the switching state of the outputs�
The measuring distance is displayed in the set unit�
Object reflectivity:
• Value range 1���99
Example:
• r99 corresponds to a white object
• r20 corresponds to a grey object
Switch between the two measured values via the "up" or "down" button�
9.2 Display mode
Indication of the parameters and the set parameter values�
► Press [ENTER] briefly�
> The unit goes to the display mode� Internally it remains in the operating mode�
The set parameter values can be read:
► To scroll through the parameters, press the "up"/"down" button briefly�
► To display the parameter value, press [Enter] briefly�
> After another 15 s the unit returns to the run mode�
9.3 Programming mode
Setting the parameter values → 10.1 General parameter setting.
42