Télécharger Imprimer la page

Autosen AL010 Notice D'utilisation page 48

Io-link

Publicité

Les langues disponibles

Les langues disponibles

10.2.8 Window function
It is possible to define a window for the object recognition for each of the two
outputs (OUT1 / OUT2)�
Switches when the object is detected
[Fno]
[nPx] = switch point "near"; [FPx] = switch point "far"; FE = window
If the measured value is between the switch point "near" [nPx] and the switch point
"far" [FPx], the output is closed (when [OUx] = [Fno])�
Switches off when the object is detected
[Fnc]
[nPx] = switch point "near"; [FPx] = switch point "far"; FE = window
If the measured value is between the switch point "near" [nPx] and the switch point
"far" [FPx], the output is open (when [OUx] = [Fnc])�
The parameters [nP1] and [FP1] can also be set via the teach function�
The reset points are set dynamically by the sensor → 10.2.7 Dynamic
hysteresis�
The minimum distance between [nP1] and [FP1] is 1 mm�
Condition: nP1 < FP1
The teaching of nP1 > FP1 will not be adopted by the sensor�
48
[nPx]
[FPx]