Derating pressure and temperature ranges
Usage limits of the armature (derating medium pressure)
Temperature
–10...+50 °C
100 °C
150 °C
200 °C
230 °C
Tab. 3:
Derating the medium pressure as per DIN EN 12516-1/PN25
Temperature
–29...+38 °C
50 °C
100 °C
150 °C
200 °C
230 °C
Tab. 4:
Derating the medium pressure as per ASME B16.5/
ASME B16.34 Cl.150
8
All manuals and user guides at all-guides.com
Medium pressure
25 bar
24.5 bar
22.4 bar
20.3 bar
19 bar
Medium pressure
19 bar
18.4 bar
16.2 bar
14.8 bar
13.7 bar
12.7 bar
English
Type 2060, 2061
Technical data
Temperature
–10...+50 °C
100 °C
150 °C
200 °C
230 °C
Tab. 5:
Derating the medium pressure as per JIS B 2220 10K
140
130
120
110
100
90
80
70
60
50
0
20
40
60
80 100 120 140 160 180 200 220
Medium temperature [
Fig. 2:
Derating VA actuator ANTG 50, 70, 90, 130
Medium pressure
14 bar
14 bar
13.4 bar
12.4 bar
11.7 bar
°C
]