Technical specifications of electric cables (note 1)
Devices
Terminals
A
Safety
photocells
B
Control
pushbutton
C
Safety pushbutton
– sensitive edges –
etc.
Note 1 – The cables required for the set-up of the system (not included in the pack) may vary according to the quantity and type
of devices envisaged for the installation..
Note 2 – The connections to terminals 1-2 (Stop), 4-5 (Step-step) and 3-5 (Photo) can be made using a single cable with several
internal wires.
CAUTION!–
The cables used must be suited to the installation environment; for example a cable type H03VV-F for indoor envi-
ronments is recommended.
All manuals and user guides at all-guides.com
Function
3 - 5
PHOTO input
3 - 4
Input
STEP-STEP
1 - 2
STOP Input
B
A
A
C
Cable type
TX Cable 2 x 0,25 mm
2
RX Cable 3 x 0,25 mm
2
Cable 2 x 0,25 mm
2
Cable 2 x 0,25 mm
2
Maximum admissible length
20 m (note 2)
20 m (note 2)
20 m (note 2)
20 m (note 2)