Pentair MYERS PQP10 Notice D'utilisation page 4

Pompes centrifuges auto-amorçantes résistant à la corrosion
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Priming plug
Priming tee
Suction
pipe
20' (6 m) max.
10-20' (3-6 m)
At least 5 feet (1.5 m)
Foot
Valve
figure 5 – cased/Dug Well installation
NOticE: Use the installation method below which
matches your well type.
caSED WEll iNStallatiON
1. Inspect foot valve to be sure it works freely. Inspect
strainer to be sure it is clean.
2. Connect foot valve and strainer to the first length of
suction pipe and lower pipe into well. Add sections
of pipe as needed, using PTFE pipe thread sealant
tape on male threads. Be sure that all suction pipe
is leakproof or pump will lose prime and fail to pump.
Install foot valve 10 to 20 feet below the lowest level
to which water will drop while pump is operating
(pumping water level). Your well driller can furnish
this information.
3. To prevent sand and sediment from entering the
pumping system, the foot valve/strainer should be at
least 5 feet above the bottom of the well.
4. When the proper depth is reached, install a sanitary
well seal over the pipe and in the well casing.
Tighten the bolts to seal the casing.
5. When using a foot valve, a priming tee and plug as
shown in Figure 5 are recommended.
DUG WEll iNStallatiON
Same as cased well installation.
DriVEN POiNt iNStallatiON
1. Connect the suction pipe to the drive point as
illustrated in Figure 6. Keep horizontal pipe run as
short as possible. Use PTFE pipe thread sealant
tape on male pipe threads. Multiple well points may
be necessary to provide sufficient water to pump.
Well Pipe installation
Check valve
Standing water
level (pump off)
Drawdown water
level (pump on)
828 0993
figure 6 – Driven Point installation
Priming
Plug
Steel drive pipe
Drive coupling
Driven point
745 0993
2. Install a check valve in horizontal pipe. Flow arrow
on check valve must point toward pump.
HOriZONtal PiPiNG frOM WEll tO PUMP
1. Never install a suction pipe that is smaller than the
suction port of the pump.
2. To aid priming on well point installations, install
a line check valve as shown in Figure 6. Be sure
check valve flow arrow points toward pump.
DiScHarGE PiPE SiZES
1. If increasing discharge pipe size, install reducer in
pump discharge port. Do not increase pipe size by
stages.
2. When the pump is set away from the points of water
use, the discharge pipe size should be increased to
reduce pressure losses caused by friction.
• Up to 100' run: Same size as pump discharge port.
• 100' to 300' run: Increase one pipe size.
• 300' to 600' run: Increase two pipe sizes.
laWN SPriNKliNG aPPlicatiON
This pump is designed for lawn sprinkling. It is
designed to deliver plenty of water at full sprinkler
pressure. It can pump from a pond, cistern or well
points.
Pump discharge can be divided to supply two (2)
or more sprinkler systems. A suggested multiple
discharge to service is shown in Figure 7.
Do not use in a pressure tank or booster pump
application.
4
To
Service
Gate
Valve
figure 7 – Multiple Discharge
561 0405

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Myers pqp15Myers pqp20Myers pqp25

Table des Matières