ENGLISH
4
Take out of service -
prepare for winter
Follow the instructions below if the E-POD motor is to be taken out
of service for a long time. Long-term means a period longer than 3
months, for example during the winter period.
Make sure the motor compartment is ventilated. Good ventilation
prevents moisture in the motor compartment. This prevents corro-
sion.
Carry out the necessary maintenance work before taking the motor
out of service for a long time. Checks and maintenance work to be
carried out:
• Clean the motor with a cloth.
The cover plate of the E-POD motor is splashproof.
• Disconnect the batteries, fully charge them and grease the bat-
tery terminals. Store the batteries in a dry and frost-free place.
4.1
Electrical System
• If necessary, regularly charge the batteries during the winter!
• For checking and maintenance of the batteries, follow the recom-
mendations of the battery supplier.
5
Put into service - prepare for summer
When putting the motor back into service, for example at the begin-
ning of the boating season, the motor must be checked and mainte-
nance work carried out.
• Check and reconnect the batteries.
• Check the operation of the motor.
• Check the operation of the instruments and motor controls.
5.1
Electrical system
• Check the voltage of each individual battery. In case of large volt-
age deviations, the batteries should be charged separately.
• Connect the batteries and fully charge the 48 volt battery bank.
5.2
Test run
Only test the E-POD motor if you are sure that people are at a
safe distance from the propeller!
• Switch on the E-POD motor and check correct operation.
• Also check the operation of the connected panels.
10
370801.01
n
ote
W
arninG
6
Troubleshooting
Malfunctions of the E-POD motor are in most cases caused by incor-
rect operation or insufficient maintenance.
In the event of a malfunction, always first check whether all operating
and maintenance instructions have been followed.
If you are unable to determine the cause of a fault or rectify a fault
yourself, please contact the nearest service representative.
Before starting, make sure that nobody is in the immediate
vicinityof the motor.
If necessary, disconnect the battery cables!
E-POD motor does not run
Possible cause
Defective or discharged battery.
Fuse burned out.
Loose or corroded connections
in the starter circuit.
Poor electrical connection.
Defective starter switch.
Jammed parts.
Short circuit due to reverse polar-
ity.
D
anGer
Solution
Check / recharge battery and
check battery charger.
Check the system. Replace
the fuse. If a replacement fuse
blows again, this indicates an
electrical problem. Have the
system checked by an installer.
Clean and secure the connec-
tions.
Repair.
Check / replace.
Repair.
Irreparable damage to motor
controller. Replace MCVB and all
connected panels.
User manual E-POD electric propulsion