2 - Change the connections of the terminal board
(C) as shown in the diagram.
3 - Undo the screws (D) to remove the lid (E).
C
C
6 - Undo the screws (G) to remove the lid (H).
7 - Use lever (L) to set the overload cutout to
1 A.
8 - Replace the lid and retighten the screws.
9 - Replace the control panel (B).
IT
GB
DE
FR
ES
10 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used
Important
On completion of the operation make sure
that there are no malfunctions.
English
400V/3N
230V/3
4 - Fit the jumper (F) to make the electrical connec-
tion of the terminals.
5 - Replace the lid and retighten the screws.
E