Télécharger Imprimer la page

Sentiotec Pro-B2 Instructions De Montage Et Mode D'emploi page 13

Masquer les pouces Voir aussi pour Pro-B2:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
Instructions for installation and use
p. 9/30
3.4. Sensor operating modes
The sauna control unit can be operated with one or two temperature sensors.
Single-sensor mode (F1)
Single-sensor mode must be activated when starting up the sauna for the first
time (see 8.3. Activating/deactivating the single-sensor mode on page 22).
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. In single-sensor mode, the sauna
control unit only displays the set temperature. The actual temperature is not dis-
played. Should the sauna control unit display the temperature above the heater
(F1) as an actual temperature in single-sensor mode, it must be activated when
starting up for the first time (see 8.4. Displaying the heater temperature in
single-sensor mode on page 22)
Two-sensor mode with bench sensor (F2)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
EN
the temperature measured by the bench sensor as the actual temperature.

Publicité

loading

Ce manuel est également adapté pour:

Pro-b31-015-4551-015-457