4
Parameter setting
Checking the parameters are correct
l
1
Press and hold the button on the remote control.
2
Press the button again so that the 2 gate leaves stop mid-travel.
3
Switch off the power supply for at least 5 seconds.
4
Restore the power supply.
5
Press and hold the button on the remote control again.
the gate leaves MUSt move in the direction of opening.
If the gate does not open correctly:
• The
gate
leaf
which
starts
• The
gate
leaf
which
starts
After reversing the wiring on one or both motors, the gate travel programming procedure
must be restarted.
to do this, one remote control must be reprogrammed (see page 11).
o Adjusting the automatic mode.
Precautions for use
l
To use your gate in automatic mode, standard EN 12 453 requires the following accessories to be
installed, connection is provided on your SGS:
• a set of photoelectric cells (see description
and wiring information on page 15),
• an orange light (see description and wiring information
on page 16),
• area lighting.
For solar power, see page 19.
Automatic mode
l
After opening, the gate leaf automatically closes again after a time delay
advance.
Automatic mode will be operational after wiring the cells and carrying out the settings below:
• Fit one remote control on the target
1
engraved on the motor cover.
> The AUto indicator light is off.
• Press and hold (> 5 sec) the remote
2
control until the AUto indicator light
comes on. Release the button.
> The AUto indicator light flashes.
first
(controlled
by
M1)
begins
► reverse the wires on the M1 motor.
second
(controlled
by
M2)
begins
► reverse the wires on the M2 motor.
which you define in
PROG
AUTO
ON/OFF
PROG
AUTO
ON/OFF
4
Parameter setting
• Begin opening (normal remote ope-
3
ning) using the remote control.
> The gate opens at normal speed..
Once the gate is fully open:
4
- Wait for the required delay time.
- Press (briefly or press and hold) the remote control button to close the gate.
> The two gate leaves close almost simultaneously.
> The AUto indicator light remains permanently on.
to
close
to
close
Automatic mode is now operational.
o Switching from automatic mode to sequential mode.
To return to sequential mode (the AUTO indicator light is lit):
• Fit the remote control on the target engraved on the cover.
• Press any button on the remote control until the AUTO indicator light goes off.
> Sequential mode is active.
STOP
PROG
AUTO
ON/OFF
o Validating the settings.
After completing one full cycle without interruption, secure the mechanical settings by locking the
gate left bracket using the 3rd hole:
Mark the central point.
1
Drill a hole in the gate leaves with
Ø 6.
Check before proceeding to the next step
On closing, check that the gate does not open again.
PROG
AUTO
ON/OFF
Fix the bracket. Reinstall the cylinder.
5
6
8
2
14
PROG
AUTO
ON/OFF
13